انتقل إلى المحتوى الرئيسي

BeyondTrust pre-auth RCE

Unauthenticated command execution in BeyondTrust remote access products

Disclosed on 2026-02-06. Hacktron says its agents identified the flaw through AI-enabled variant analysis, part of autonomous scans it runs across enterprise software. Within a week it was in CISA KEV with known ransomware use.

Copy a defensive prompt

VERIFIED EVENT RECORD

Event facts

CVE records
CVSS
CVSS 4.0 · 9.9 · BeyondTrust
Affected
Remote Support ≤ 25.3.1; PRA ≤ 24.3.4
Fixed versions
Remote Support 25.3.2, PRA 25.1.1, patch BT26-02
Disclosed
2026-02-06
Last verified
2026-11-23
CISA KEV
Listed · 2026-02-13
Exploitation status
Confirmed exploitation
Discoverers
Hacktron
AI systems
Hacktron agents
AI involvement
AI found, human verified

Impact

The CVE record says an unauthenticated remote attacker may be able to execute operating system commands in the context of the site user.

Recommended action

Apply patch BT26-02 or upgrade to Remote Support 25.3.2 or PRA 25.1.1. Self-hosted instances that were internet-facing before patching should be reviewed for compromise.

PRIMARY SOURCES

Sources and verification links

DEFENSIVE PROMPT KIT

Prompts for a coding agent inside your environment

Choose a task and copy the complete prompt into Claude Code, Codex, or a similar tool that can read your own repositories and servers. The current event list is inserted automatically.

Prompt content

Task: determine whether my environment is affected by the events below.

Event data:
- BeyondTrust pre-auth RCE (BeyondTrust Remote Support / PRA)
  CVEs: CVE-2026-1731
  Fixed versions: Remote Support 25.3.2, PRA 25.1.1, patch BT26-02
  Source: https://www.beyondtrust.com/trust-center/security-advisories/bt26-02

Inventory repositories, lockfiles, container images, package manifests, service configuration, public entry points, and running versions. Compare affected ranges, required conditions, and fixed versions. For every conclusion, show the evidence, confidence, and information a person still needs to provide.

Rules: Work only on systems the user owns or is authorised to manage. Remain read-only until a person approves. Produce a plan and evidence first. Never change production, restart services, or rotate secrets without explicit approval. Confirm every fact at the vendor advisory and CVE record instead of relying on memory. Record what you checked and what you could not check. Do not scan third-party hosts or run attack simulations.

What this prompt covers

The prompt asks an agent to inventory, verify facts, and prepare a plan. It grants no permission to modify production and does not replace the vendor advisory, CVE record, national CERT, or your change process.

OPERATIONALIZE THE RESPONSE

Turn this response into a continuing workflow

Tenten can connect asset inventory, source monitoring, exposure verification, and human approval to your existing engineering process.

Discuss a Security Watch workflow

Defensive information

This page contains defensive information and is not an official advisory. Versions, patches, and exploitation status can change. Check the vendor advisory, CVE record, and your national CERT before acting.